Test Instruments Total Products: 11531
Sub Collections
Voltage Detector CAT IV 600V No Disp
FLUKEVoltage Detector Alert Type Light Built-In Flashlight Yes CAT Safety Rating CAT IV 600V Cable Length Not Applicable Display Type No Display Maximum...
View full DetailsSurface Temp Probe -19.3 to 302 Deg F
FLUKESurface Temperature Probe Type K For Application Air Surface Mini Pin Probe Size 19 1/2 in Cable Length 40 in -19.3 Degrees to 302 Degrees F/-30 De...
View full DetailsAC Flexible Current Probe PK4
FLUKEFlexible Current Probe Connector Type BNC For Use With Digital Power Quality Analyzers Maximum AC Current Measurement 3 000 A Minimum AC Current Me...
View full DetailsAC Flexible Current Probe 20/200/2000A
FLUKEFlexible Current Probe Connector Type Safety Plugs For Use With Fluke 175 Fluke 177 Fluke 179 Fluke 233 Fluke 27 II Fluke 28 II Fluke 287 Fluke 289...
View full DetailsHandheld Digital Manometer 0to 200 in wc
DWYERHandheld Digital Manometer Maximum Pressure 200 in wc Minimum Pressure 0 in wc Pressure Accuracy +/-0.5 Percent Process Connection Size 1/8 in 3/16...
View full DetailsHandheld Digital Manometer 0 to 20 in wc
DWYERHandheld Digital Manometer Maximum Pressure 20 in wc Minimum Pressure 0 in wc Pressure Accuracy +/-0.5 Percent Process Connection Size 1/8 in 3/16 ...
View full DetailsData View Logger Temp and Humidity
SUPCOData View Logger Humidity Temperature Temp Range (F) 15 Degrees to 150 Degrees F Relative Humidity Range 0 Percent to 90 Percent Dew Point Range +/...
View full DetailsMini Data Logger Temperature -40 To 160F
SUPCOMini Data Logger Temperature Temp Range (F) -40 Degrees to 160 Degrees F Voltage Range 3 V Accuracy +/-1 Degrees F Time Intervals 1 sec to 18 hr In...
View full DetailsThermocouple Thermometer 2 Input Type K
EXTECHThermocouple Thermometer Thermocouple Number of Channels 2 Includes NIST-Traceable Certificate No Accuracy +/-0.3 Percent +2 Degrees F/1 Degrees C ...
View full DetailsPocket Digital Multimeter 200mA
EXTECHDigital Multimeter Audible Continuity Yes Basic AC Voltage Accuracy +/-1.50 Percent Basic DC Voltage Accuracy +/-0.80 Percent Data Hold No Basic DC...
View full DetailsMini Digital Multimeter 600V 40 MOhms
EXTECHDigital Multimeter Audible Continuity Yes Basic AC Voltage Accuracy +/-0.5 Percent Basic DC Voltage Accuracy +/-0.50 Percent Data Hold Yes Basic DC...
View full DetailsMini Digital Multimeter 600V 2000 KOhms
EXTECHDigital Multimeter Audible Continuity Yes Basic AC Voltage Accuracy +/-0.5 Percent Basic DC Voltage Accuracy +/-0.50 Percent Data Hold Yes Basic DC...
View full DetailsChart 8 In -50 to +50 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range -50 to +50 Recording Time 24 Hr For Use With 1APA6 - 1APA8 and 1APB1 Package Quantity 60
Chart 8 In -50 to +50 7 Day PK60
DICKSONCircular Paper Chart Chart Size 8 In Range -50 to +50 Recording Time 7 Day For Use With 1APA6 - 1APA8 and 1APB1 Package Quantity 60
Chart 8 In 0 to 250 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 250 Recording Time 24 Hr For Use With 1APA6 - 1APA9 and 1APB1 Package Quantity 60
Chart 8 In 0 to 500 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 500 Recording Time 24 Hr For Use With 1APA7 - 1APA9 and 1APB1 Package Quantity 60
Chart 8 In 0 to 500 7 Day PK60
DICKSONCircular Paper Chart Chart Size (In.) 8 Range 0 Degrees to 500 Degrees F/C Recording Time (Day) 7 For Use With 1APA7-1APA9 1APB1 1NFJ6 and 3FDF6
Temperature Probe Piercing U/W 1PRT9
DICKSONTemperature Probe Piercing For Use With 1PRT9 Features 316 Stainless Steel Shaft 4 in Long 5 Ft Coiled Cable Temp Range to +1650 Degrees F or +900 ...
View full DetailsChart 8 In 0 to 1000 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 1000 Recording Time 24 Hr For Use With 1APA9 Package Quantity 60
Chart 8 In 0 to 1000 7 Day PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 1000 Recording Time 7 Day For Use With 1APA9 Package Quantity 60
Chart 8 In 0 to 2000 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 2000 Recording Time 24 Hr For Use With 1APA9 Package Quantity 60
Chart 8 In 0 to 2000 7 Day PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 2000 Recording Time 7 Day For Use With 1APA9 Package Quantity 60
Chart 8 In 0 to 100 24 Hr PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 100 Recording Time 24 Hr For Use With 1APA6 - 1APA8 and 1APB1 Package Quantity 60
Chart 8 In 0 to 100 7 Day PK60
DICKSONCircular Paper Chart Chart Size 8 In Range 0 to 100 Recording Time 7 Day For Use With 1APA6 - 1APA8 and 1APB1 Package Quantity 60