Single-Gas Detection Tubes and Chips Total Products: 476
Filters
- 10 (1)
- 17 (1)
- 30 (1)
- 35 (1)
- 40 (1)
- 101 (1)
- 103 (1)
- 105 (1)
- 106 (1)
- 113 (1)
- 122 (1)
- 123 (1)
- 128 (1)
- 159 (1)
- 171 (1)
- 180 (1)
- 183 (1)
- 6406010 (1)
- 6406020 (1)
- 6406050 (1)
- 6406070 (1)
- 6406080 (1)
- 6406090 (1)
- 6406110 (1)
- 6406120 (1)
- 6406150 (1)
- 6406160 (1)
- 6406170 (1)
- 6406190 (1)
- 6406200 (1)
- 6406210 (1)
- 6406250 (1)
- 6406270 (1)
- 6406320 (1)
- 8103571 (2)
- 17158960 (1)
- 1A (1)
- 11A (1)
- 100A (1)
- 100B (1)
- 2D (1)
- 3D (1)
- 4D (1)
- 14D (1)
- 32D (1)
- 133D (1)
- 152D (1)
- 5DH (1)
- 122DL (1)
- 1H (1)
- 3H (1)
- 5H (1)
- 2HH (1)
- 4HH (1)
- 3HM (1)
- 2HT (1)
- 4HT (1)
- 1L (1)
- 2L (1)
- 3L (1)
- 4L (1)
- 5L (1)
- 11L (1)
- 12L (1)
- 14L (1)
- 15L (1)
- 18L (1)
- 101L (1)
- 102L (1)
- 112L (1)
- 122L (1)
- 124L (1)
- 133L (1)
- 138L (1)
- 165L (1)
- 191L (1)
- 3LA (1)
- 5LA (1)
- 19LA (1)
- 21LA (1)
- 136LA (1)
- 131LB (1)
- 2LC (1)
- 1LKC (1)
- 1LL (1)
- 2LL (1)
- 4LL (1)
- 1LM (1)
- 4LT (1)
- 3M (1)
- 4M (1)
- 5M (1)
- 14M (1)
- 18M (1)
- 132M (1)
- 121P (1)
- 4S (1)
- 11S (1)
- 45S (1)
- 121SP (1)
Tube Xylene 5-625 PK10
GASTECDetector Tube Measurement Range 5 to 625 ppm Gas Detected Xylene For Use With Gastec Pump Color Change White to Brown Operating Pressure 912 to 1 1...
View full DetailsTube Vinyl Chloride 0.25-40 PK10
GASTECDetector Tube Measurement Range 0.4 to 70 ppm Gas Detected Vinyl Chloride For Use With Gastec Pump Color Change Yellow to Purple Operating Pressure...
View full DetailsDetector Chip Mercaptan
DRAEGERDetector Chip Measurement Range 0.25 to 6 ppm Gas Detected Mercaptans For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Tempe...
View full DetailsDetector Chip Hydrogen Sulfide
DRAEGERDetector Chip Measurement Range 0.2 to 5 ppm Gas Detected Hydrogen Sulfide For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating ...
View full DetailsDetector Chip Ethylene Oxide
DRAEGERDetector Chip Measurement Range 0.4 to 5 ppm Gas Detected Ethylene Oxide For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Te...
View full DetailsDetector Chip Ethanol
DRAEGERDetector Chip Measurement Range 100 to 2 500 ppm Gas Detected Ethanol For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Tempe...
View full DetailsDetector Chip Carbon Dioxide
DRAEGERDetector Chip Measurement Range 1 to 20 Percent vol Gas Detected Carbon Dioxide For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Opera...
View full DetailsDetector Chip Butadiene
DRAEGERDetector Chip Measurement Range 1 to 25 ppm Gas Detected Butadiene For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Temperat...
View full DetailsDetector Chip Ammonia
DRAEGERDetector Chip Measurement Range 0.2 to 5 ppm Gas Detected Ammonia For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Temperatu...
View full DetailsPerc Tetrachloroethylene Dosimeter PK10
GASTECDetector Tube Measurement Range 3 to 150 ppm Gas Detected Tetrachloroethylene For Use With Dosiholder Color Change Yellow to Purple Operating Press...
View full DetailsMethyl Ethyl Ketone Dosimeter 2-600 PK10
GASTECDetector Tube Measurement Range 2 to 600 ppm Gas Detected Methyl Ethyl Ketone For Use With Dosiholder Color Change Yellow to Reddish Brown Operatin...
View full DetailsHydrogen Sulfide Dosimeter 0.2-200 PK10
GASTECDetector Tube Measurement Range 0.2 to 200 ppm Gas Detected Hydrogen Sulphide For Use With Dosiholder Color Change White to Brown Operating Pressur...
View full DetailsHydrogen Peroxide Dosimeter Tube PK10
GASTECDetector Tube Measurement Range 0.5 to 40 ppm Gas Detected Hydrogen Peroxide For Use With Dosiholder Color Change White to Yellow Operating Pressur...
View full DetailsHydrogen Chloride Dosimeter 1-100 PK10
GASTECDetector Tube Measurement Range 1 to 100 ppm Gas Detected Hydrogen Chloride For Use With Dosiholder Color Change Yellow to Purple Operating Pressur...
View full DetailsFormaldehyde Dosimeter Tube 0.1-20 PK10
GASTECDetector Tube Measurement Range 0.1 to 20 ppm Gas Detected Formaldehyde For Use With Dosiholder Color Change Yellow to Reddish Brown Operating Pres...
View full DetailsCarbon Dioxide Dosimeter 0.02-16 PK10
GASTECDetector Tube Measurement Range 0.02 to 12 Percent Gas Detected Carbon Dioxide For Use With Dosiholder Color Change Pale Orange Red to Yellow Opera...
View full DetailsCMS Chip Vinyl Chloride 0.3-10 ppm
DRAEGERDetector Chip Measurement Range 0.3 to10 ppm Gas Detected Vinyl Chloride For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Te...
View full DetailsCMS Chip Sulfur Dioxide 0.4-10 ppm
DRAEGERDetector Chip Measurement Range 0.4 to10 ppm Gas Detected Sulfur Dioxide For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Te...
View full DetailsCMS Chip Pet. Hydrocarbons 20-500 ppm
DRAEGERDetector Chip Measurement Range 20 to 500 ppm Gas Detected Petroleum Hydrocarbons For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Ope...
View full DetailsCMS Chip Hydrogen Sulfide 2.0-50 ppm
DRAEGERDetector Chip Measurement Range 2.0to50 ppm Gas Detected Hydrogen Sulfide For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating T...
View full DetailsCMS Chip Chlorine 0.2-10 ppm
DRAEGERDetector Chip Measurement Range 0.2 to 10 ppm Gas Detected Chlorine For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Tempera...
View full DetailsCMS Chip Benzene 0.5-10 ppm
DRAEGERDetector Chip Measurement Range 0.5 to 10 ppm Gas Detected Benzene For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Temperat...
View full DetailsCMS Chip Ammonia 10-150 ppm
DRAEGERDetector Chip Measurement Range 10 to 150 ppm Gas Detected Ammonia For Use With CMS Analyzer Operating Pressure 700 to 1 100 hPa Operating Temperat...
View full DetailsDetector Tube C3H3N 0.5 to 20 ppm PK10
DRAEGERDetector Tube Measurement Range 0.2 to 4 ppm/5 to 50 ppm Gas Detected Acrylonitrile For Use With Mfr No 4523617 Mfr No 6400000 Color Change Yellow ...
View full Details