Single-Gas Detection Tubes and Chips Total Products: 470
Filters
- 10 (1)
- 17 (1)
- 30 (1)
- 35 (1)
- 40 (1)
- 101 (1)
- 103 (1)
- 105 (1)
- 106 (1)
- 113 (1)
- 122 (1)
- 123 (1)
- 128 (1)
- 159 (1)
- 171 (1)
- 180 (1)
- 183 (1)
- 8103571 (2)
- 17158960 (1)
- 1A (1)
- 11A (1)
- 100A (1)
- 100B (1)
- 2D (1)
- 3D (1)
- 4D (1)
- 14D (1)
- 32D (1)
- 133D (1)
- 152D (1)
- 5DH (1)
- 122DL (1)
- 1H (1)
- 3H (1)
- 5H (1)
- 2HH (1)
- 4HH (1)
- 3HM (1)
- 2HT (1)
- 4HT (1)
- 1L (1)
- 2L (1)
- 3L (1)
- 4L (1)
- 5L (1)
- 11L (1)
- 12L (1)
- 14L (1)
- 15L (1)
- 18L (1)
- 101L (1)
- 102L (1)
- 112L (1)
- 122L (1)
- 124L (1)
- 133L (1)
- 138L (1)
- 165L (1)
- 191L (1)
- 3LA (1)
- 5LA (1)
- 19LA (1)
- 21LA (1)
- 136LA (1)
- 131LB (1)
- 2LC (1)
- 1LKC (1)
- 1LL (1)
- 2LL (1)
- 4LL (1)
- 1LM (1)
- 4LT (1)
- 3M (1)
- 4M (1)
- 5M (1)
- 14M (1)
- 18M (1)
- 132M (1)
- 121P (1)
- 4S (1)
- 11S (1)
- 45S (1)
- 121SP (1)
- 6406010 (0)
- 6406020 (0)
- 6406050 (0)
- 6406070 (0)
- 6406080 (0)
- 6406090 (0)
- 6406110 (0)
- 6406120 (0)
- 6406150 (0)
- 6406160 (0)
- 6406170 (0)
- 6406190 (0)
- 6406200 (0)
- 6406210 (0)
- 6406250 (0)
- 6406270 (0)
- 6406320 (0)
Detector Tube Hydrocrbns 0.1Percent PK10
DRAEGERDetector Tube Measurement Range 0.1 to 1.3 Percent vol Propane 0.1 to 1.3 Percent vol Butane 0.1 to 1.3 Percent vol mix 1 1 Gas Detected Hydrocarbo...
View full DetailsDetector Tube Ethylene 0.1 to 5 ppm PK10
DRAEGERDetector Tube Measurement Range 0.2 to 5 ppm Gas Detected Ethylene For Use With Draeger Accuro Pump Color Change Pale Yellow to Grayish Blue Operat...
View full DetailsDetector Tube Carbon Disulfide PK10
DRAEGERDetector Tube Measurement Range 5 to 60 ppm Gas Detected Carbon Disulfide For Use With Draeger Accuro Pump Color Change White to Brown Green Operat...
View full DetailsDetector Tube Benzene 2 to 60 ppm PK10
DRAEGERDetector Tube Measurement Range 2 to 60 ppm Gas Detected Benzene For Use With Draeger Accuro Pump Color Change White to Brown Gray Operating Pressu...
View full DetailsTube Trichloroethylene 2-250 PK10
GASTECDetector Tube Measurement Range 2 to 270 ppm Gas Detected Trichloroethylene For Use With Gastec Pump Color Change Yellow to Reddish Purple Operatin...
View full DetailsTube Acrylonitrite 1-80 PK10
GASTECDetector Tube Measurement Range 0.1 to 18 ppm Gas Detected Acrylonitrile For Use With Gastec Pump Color Change Yellow to Pink Operating Pressure 91...
View full DetailsTube Toluene 1-100 PK10
GASTECDetector Tube Measurement Range 1 to 100 ppm Gas Detected Toluene For Use With Gastec Pump Color Change White to Brown Operating Pressure 912 to 1 ...
View full DetailsTube Toluene 5-600 PK10
GASTECDetector Tube Measurement Range 5 to 690 ppm Gas Detected Toluene For Use With Gastec Pump Color Change White to Brown Operating Pressure 912 to 1 ...
View full DetailsTube Tetrahydrofuran 20-800 PK10
GASTECDetector Tube Measurement Range 25 to 800 ppm Gas Detected Tetrahydrofuran For Use With Gastec Pump Color Change Pale Orange Red to Pale Blue Opera...
View full DetailsTube Sulfuric Acid 1-5mg/m3 PK10
GASTECDetector Tube Measurement Range 0.5 to 5 mg/m3 Gas Detected Sulfuric Acid For Use With Gastec Pump Color Change Pale Yellow to Reddish Purple Opera...
View full DetailsTube Sulfur Dioxide 20-3600 PK10
GASTECDetector Tube Measurement Range 20 to 3600 ppm Gas Detected Sulphur Dioxide For Use With Gastec Pump Color Change Purple to Yellow Operating Pressu...
View full DetailsTube Sulfur Dioxide 1.25-200 PK10
GASTECDetector Tube Measurement Range 1.25 to 200 ppm Gas Detected Sulphur Dioxide For Use With Gastec Pump Color Change Blue to Yellow Operating Pressur...
View full DetailsTube Styrene 2-100 PK10
GASTECDetector Tube Measurement Range 2 to 100 ppm Gas Detected Styrene For Use With Gastec Pump Color Change White to Yellow Operating Pressure 912 to 1...
View full DetailsTube Stoddard Solvent 50-8000mg/m3 PK10
GASTECDetector Tube Measurement Range 50 to 8 000 mg/m3 Gas Detected Stoddard Solvent For Use With Gastec Pump Color Change White to Brown Operating Pres...
View full DetailsDetector Tube Propane PK10
GASTECDetector Tube Measurement Range 0.1 to 2 Percent vol Gas Detected Propane For Use With No 611 Syringe Color Change Yellowish Brown to Greenish Brow...
View full DetailsTube Phosphine 0.05-9.8 PK10
GASTECDetector Tube Measurement Range 0.05 to 9.8 ppm Gas Detected Phosphine For Use With Gastec Pump Color Change Yellow to Red Operating Pressure 912 t...
View full DetailsTube Perchloroethylene 1-70 PK10
GASTECDetector Tube Measurement Range 1 to 75 ppm Gas Detected Tetrachloroethylene For Use With Gastec Pump Color Change Yellow to Pink Operating Pressur...
View full DetailsTube Ozone 4-400 PK10
GASTECDetector Tube Measurement Range 4 to 400 ppm Gas Detected Ozone For Use With Gastec Pump Color Change Orange to Pale Yellow Operating Pressure 912 ...
View full DetailsTube Nitrogen Dioxide 0.5-125 PK10
GASTECDetector Tube Measurement Range 2.5 to 200 ppm Gas Detected Nitrogen Dioxide Nitrogen Oxide For Use With Gastec Pump Color Change White to Yellowis...
View full DetailsTube n-Hexane 10-1200 PK10
GASTECDetector Tube Measurement Range 4 to 1 200 ppm Gas Detected Hexane For Use With Gastec Pump Color Change Yellowish Brown to Greenish Brown Operatin...
View full DetailsTube Methylene Chloride 10-150 PK10
GASTECDetector Tube Measurement Range 4 to 150 ppm Gas Detected Methylene Chloride For Use With Gastec Pump Color Change White to Pale Pink Operating Pre...
View full DetailsTube Methyl Bromide 1-36 PK10
GASTECDetector Tube Measurement Range 1 to 36 ppm Gas Detected Methyl Bromide For Use With Gastec Pump Color Change White to Yellow Operating Pressure 91...
View full DetailsTube Mercury Vapor 0.05-13.2mg/m3 PK10
GASTECDetector Tube Measurement Range 0.05 to 13.2 mg/m3 Gas Detected Mercury Vapor For Use With Gastec Pump Color Change White to Pale Orange Operating ...
View full DetailsTube Hydrogen Sulfide 12.5-500 PK10
GASTECDetector Tube Measurement Range 12.5 to 500 ppm Gas Detected Hydrogen Sulphide For Use With Gastec Pump Color Change White to Brown Operating Press...
View full Details